MP32-250 Multi-parameter combination Logging Tool is mainly used in oil production and logging. This instrument consists of 01pup joint and 02 pup joint. Pressure, temperature and magnet location are measured by 01pup joint. Flow and holdup water rate are measured by 02 pup joint. Power supply of the instrument is used by a single-core cable. When logging, 01pup joint and 02pup joint are connected to go down the well. It can measure magnet location, temperature, pressure, flow and holdup water rate at one time when it goes down to the well. The instrument adopts two heat insulation barrels to log. It can be widely used in offshore and onshore well logging task with temperature not higher than 250 ℃ and the pressuresnot more than 60MPa.
Parameters
• Outer diameter: φ32mm
• Overall length: 3743mm
• Work Temperature: ≤8700PSI (≤60Mpa)
• Temperature measurement range:-40℃~+250℃
• Temperature measurement accuracy: ±1°C
• Temperature measurement resolution: 0.01°C
• Signal transmission mode: single bus, Manchester encoding
• Output signal amplitude: ±10V~ ±12V
• CCL center frequency: 20±1KHz
• CCL measurement range: 2~7inches
• Pressure measurement range: 0MPa~60MPa
• Pressure measurement accuracy: ≤0.1%FS
• Pressure resolution: 0.01MPa
• Flow measurement range:Flow measurement accuracy: ≤2.5%FS
• Flow start displacement: ≤1.5m3/day:
• Water holdup rate measurement range:0%-95%
• Water holdup rate measurement curacy: ±7%
• Max open diameter of umbrella: 5.5 inches or 7 inches casing
01section
02 section
MP32-250
Multi-parameter combination Logging Tool