YQF-100 series oil/gas separation measurement system is used for the dynamic monitoring of liquid and gas producing capacity. Separating fluid from gas adopts the advanced column shaped toroidal swirl fluid /gas separation technology . Coriolis mass flow rate measures fluid accurately.
The production series use density method and density method relevant water holdup method mathematical model to realize measurement of the water( oil ) holdup, as well as total mass of oil-water mixer ,flow rate and density.
Advantages:
• High accuracy and real time online measurement
• User-friendly ,easy movement , installation and maintenance
• Small volume and light weight
• High reliability and less maintenance
• Wide availability and range
2.1 How does it work
As figure shows ,fluid passes through jet flow port and flows into toroidal swirl separator .Due to toroidal swirl, fluid flows into the bottom of the separator while gas ascends to the top of the separator along the center of the toroidal swirl. Adjusting fluid level and pressure by self control system, realizing the separation of gas and fluid, fluid is weighted through mass flow rate and gas is weighted through gas flow rate.
According to the real time density of fluid provided by the mass flow rate, referring to the density of pure water and pure oil , the host computer analyzes and processes the measured data , automatically generating instant parameter curves of the fluid, gas , water(oil), daily report etc. Remote monitoring of measurement parameters can also be performed on requirement.
2.2 Structure
YQF-100 oil/gas separation measurement apparatus
Parameters:
3.1 Main parameters
• Flow rate range: Minimum flow rate is 1 t/d for small flow rate type and Maximum flow rate is 7200 t/d for big flow rate type
• Fluid measurement error : ≤±2%
• Water holdup relative error : ≤±3%
• Gas measurement error : ≤±2%
• Voltage rating : 362.5 PSI (2.5MPa)
• Overpressure resistant test: 580 PSI (4.0MPa)
• Power supply : 220VAC±15%,50Hz or 24VDC±10%
3.2 Usable range
• Medium viscosity: 0~12000 mPa.S
• Water holdup : 0~100%
• Medium temperature : 5~80℃
• Environment temperature : -20℃~55℃
• Environment moisture: 10~85%
3.3 Explosion proof level
• ExdⅡCT4~T6 / ExibⅡCT4~T6
3.4 Shelter level
• IP67
Model instructions
Model is used for defining flange of tool interface and flow rate range .
Model | Internal diameter |
Fluid flow rate range (t/d) |
Maximum Pressure (PSI) |
Pressure rating (PSI) |
Flange of ensor interface |
YQF-100-DN25A | DN25 | 1.0~10 | 580(4MPa) | 362.5 (2.5 MPa) | DN15 PN40 |
YQF-100-DN25B | DN25 | 4.0~30 | 580(4MPa) | 362.5 (2.5 MPa) | DN25 PN40 |
YQF-100-DN40 | DN40 | 10~240 | 580(4MPa) | 362.5 (2.5 MPa) | DN40 PN40 |
YQF-100-DN50A | DN50 | 20~320 | 580(4MPa) | 362.5 (2.5 MPa) | DN50 PN40 |
YQF-100-DN50B | DN50 | 40~900 | 580(4MPa) | 362.5 (2.5 MPa) | DN50 PN40 |
YQF-100-DN80 | DN80 | 90~1850 | 580(4MPa) | 362.5 (2.5 MPa) | DN80 PN40 |
YQF-100-DN100 | DN100 | 210~4300 | 580(4MPa) | 362.5 (2.5 MPa) | DN100 PN40 |